Matrix Test Labs is accredited by the National Accreditation Board for Testing and Calibration Laboratories (NABL) as per ISO/IEC 17025:2017. Browse, search or download our complete accredited scope below.
| S.No | Discipline / Group | Materials or Products tested | Component, parameter or characteristic tested / Specific Test Performed / Tests or type of tests performed | Test Method Specification against which tests are performed and / or the techniques / equipment used |
|---|---|---|---|---|
| Permanent Testing | ||||
| 1 | ELECTRICAL- CELLS & BATTERIES | Electrically Propelled Road Vehicles — Dimensions and Designation of Secondary Lithium-Ion Cells | Designation of cell | Cl. 5 IS 16827 : 2018 ISO/IEC PAS 16898 |
| 2 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Cell and battery designation and marking | Cl. 5 IS 16048 (Part 2) |
| 3 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Charge (capacity) retention | CL. 7.4 IS 16048 (Part 2) |
| 4 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Charge (Capacity) Retention | Cl. 7.4 IS 16048 (Part 2) |
| 5 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Charge acceptance at +55°C for LT, MT or HT cylindrical cells | Cl. 7.11 IS 16048 (Part 2) |
| 6 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Charging procedure for test purposes | Cl. 7.2 IS 16048 (Part 2) |
| 7 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Dimenions | Cl. 6 IS 16048 (Part 2) |
| 8 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Dimenions | Cl. 6 IS 16048 (Part 2) |
| 9 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Dimensions | Cl. 6 IS 16048 (Part 2) |
| 10 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Discharge performance at 0 °C | CL. 7.3.3 IS 16048 (Part 2) |
| 11 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Discharge performance at 20 °C | Cl. 7.3.2 IS 16048 (Part 2) |
| 12 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Discharge performance for rapid charge cells (R cells) | CL. 7.3.4 IS 16048 (Part 2) |
| 13 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Endurance | Cl. 7.5 IS 16048 (Part 2) |
| 14 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | General | Cl. 7.3.1 IS 16048 (Part 2) |
| 15 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | General-verification of temperature, voltage and current | Cl. 7.1 IS 16048 (Part 2) |
| 16 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Mechanical | Cl. 8 IS 16048 (Part 2) |
| 17 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Overcharge | Cl. 7.7 IS 16048 (Part 2) |
| 18 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Safety device operation | Cl. 7.8 IS 16048 (Part 2) |
| 19 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Safety requirements | Cl. 9 IS 16048 (Part 2) |
| 20 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Surface temperature limitation device operation (for S cell only) | Cl. 7.9 IS 16048 (Part 2) |
| 21 | ELECTRICAL- CELLS & BATTERIES | SECONDARY CELLS AND BATTERIES CONTAINING ALKALINE OR OTHER NON ACID ELECTROLYTES - PORTABLE SEALED RECHARGEABLE SINGLE CELLS NICKEL-METAL HYDRIDE | Trickle charge acceptance for JT cylindrical cells | Cl. 7.12 IS 16048 (Part 2) |
| 22 | ELECTRICAL- CELLS & BATTERIES | Electrically Propelled Road Vehicles — Dimensions and Designation of Secondary Lithium-Ion Cells | Designation of cell | Cl. 5 IS 16827 : 2018 ISO/IEC PAS 16898 |
| 23 | ELECTRICAL- CELLS & BATTERIES | Electrically Propelled Road Vehicles — Dimensions and Designation of Secondary Lithium-Ion Cells | Designation of cell | Cl. 5 IS 16827 : 2018 ISO/IEC PAS 16898 |
| 24 | ELECTRICAL- CELLS & BATTERIES | Electrically Propelled Road Vehicles — Dimensions and Designation of Secondary Lithium-Ion Cells | Shape of construction and constituent parts of secondary lithium-ion cell | Cl. 4 IS 16827 : 2018 ISO/IEC PAS 16898 |
| 25 | ELECTRICAL- CELLS & BATTERIES | Temperature, Voltage And Current Management | Cl. 5.4 IEC 62133-1 | |
| 26 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | Application for approval of REESS (Informative) | Cl. 4, AIS 038 (Rev 2):2020 + A1 to A4 |
| 27 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | External short circuit protection | Cl. 6.6, AIS 038 (Rev 2):2020 + A1 to A4 |
| 28 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | Low-temperature protection | Cl. 6.11, AIS 038 (Rev 2):2020 + A1 to A4 |
| 29 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | Mechanical Shock- Acceptance criteria | Cl. 6.4.1.3, AIS 038 (Rev 2):2020 + A1 to A4 |
| 30 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | Mechanical Shock- Component based test | Cl. 6.4.1.2, AIS 038 (Rev 2):2020 + A1 to A4 |
| 31 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | Overcharge protection | Cl. 6.7, AIS 038 (Rev 2):2020 + A1 to A4 |
| 32 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | Overcurrent protection | Cl. 6.10, AIS 038 (Rev 2):2020 + A1 to A4 |
| 33 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | Over-discharge protection | C. 6.8, AIS 038 (Rev 2):2020 + A1 to A4 |
| 34 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | Over-temperature protection | Cl. 6.9, AIS 038 (Rev 2):2020 + A1 to A4 |
| 35 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | Requirements Of A Rechargeable Electrical Energy Storage System (Reess) With Regard To Its Safety-General | Cl. 6.1, AIS 038 (Rev 2):2020 + A1 to A4 |
| 36 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | Thermal propagation | Cl. 6.15, AIS 038 (Rev 2):2020 + A1 to A5 |
| 37 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | Thermal shock and cycling | Cl. 6.3, AIS 038 (Rev 2):2020 + A1 to A6 |
| 38 | ELECTRICAL- CELLS & BATTERIES | ELECTRIC POWER TRAIN OF VEHICLES | Vibration | Cl. 6.2, AIS 038 (Rev 2):2020 + A1 to A7 |
| 39 | ELECTRICAL- CELLS & BATTERIES | "Secondary Cells and Batteries Containing Alkaline or OtherNon- Acid Electrolytes- Secondary Lithium Cells and Batteries for Use in Industrial Applications" | Dimensions- Length | Cl 7.3.1 IEC 62620:2014 + Amd 1 |
| 40 | ELECTRICAL- CELLS & BATTERIES | "Secondary Cells and Batteries Containing Alkaline or OtherNon- Acid Electrolytes- Secondary Lithium Cells and Batteries for Use in Industrial Applications" | Dimensions- Length/Width/Height/Dia meter | Cl 7.3.1 IEC 62620:2014 + Amd 1 |
| 41 | ELECTRICAL- CELLS & BATTERIES | "Secondary Cells and Batteries Containing Alkaline or OtherNon- Acid Electrolytes- Secondary Lithium Cells and Batteries for Use in Industrial Applications" | Marking and designation | Cl 5 IEC 62620:2014 + Amd 1 |
| 42 | ELECTRICAL- CELLS & BATTERIES | Batteries for use in stationary, Vehicle auxiliary power and Light electric Rail applications | Continuity Test | Cl. 23, UL 1973 (3rd Edition) |
| 43 | ELECTRICAL- CELLS & BATTERIES | Batteries for use in stationary, Vehicle auxiliary power and Light electric Rail applications | Dielectric Voltage Withstand Test | Cl. 22, UL 1973 (3rd Edition) |
| 44 | ELECTRICAL- CELLS & BATTERIES | Batteries for use in stationary, Vehicle auxiliary power and Light electric Rail applications | Drop impact Test | Cl. 33, UL 1973 (3rd Edition) |
| 45 | ELECTRICAL- CELLS & BATTERIES | Batteries for use in stationary, Vehicle auxiliary power and Light electric Rail applications | Failure of Cooling/Thermal Stability System | Cl. 24, UL 1973 (3rd Edition) |
| 46 | ELECTRICAL- CELLS & BATTERIES | Batteries for use in stationary, Vehicle auxiliary power and Light electric Rail applications | High rate charge | Cl. 16, UL 1973 3rd edition |
| 47 | ELECTRICAL- CELLS & BATTERIES | Batteries for use in stationary, Vehicle auxiliary power and Light electric Rail applications | Imbalanced Charging Test | Cl. 21, UL 1973 (3rd Edition) |
| 48 | ELECTRICAL- CELLS & BATTERIES | Batteries for use in stationary, Vehicle auxiliary power and Light electric Rail applications | Impact Test | Cl. 32, UL 1973 (3rd Edition) |
| 49 | ELECTRICAL- CELLS & BATTERIES | Batteries for use in stationary, Vehicle auxiliary power and Light electric Rail applications | mould stress test | Cl. 35, UL 1973 (3rd Edition) |
| 50 | ELECTRICAL- CELLS & BATTERIES | Batteries for use in stationary, Vehicle auxiliary power and Light electric Rail applications | Over discharge Protection Test | Cl. 19, UL 1973 (3rd Edition) |
NABL Accredited & BIS Recognised — fast turnaround, reliable results.